Total Organic Carbon Analyzer
+
  • Total Organic Carbon Analyzer

Total Organic Carbon Analyzer

TOC-800S


The TOC-800S Total Organic Carbon (TOC) Analyzer uses high-temperature catalytic oxidation with NDIR detection. It is designed for measuring TOC concentrations in water samples ranging from 0.050 ppm to 35,000.0 ppm, featuring high sensitivity, accuracy, and good stability.


The TOC-800S is a compact instrument with main components installed on the host. Before measurement, the instrument requires gas line connection and reagent preparation. It is controlled by dedicated software running on an external computer for measurement, calibration, printing, and other data processing tasks.


Key Features

1300℃ catalytic NDIR, 0.05-35000mg/L

External PC & audit trail, GMP/21 CFR 11

Solid/auto sampler, 3-stage cond, 100g/L

Facebook
YouTube
LinkedIn
    • Brand: LabNav
    • Commodity name: Total Organic Carbon Analyzer
    • Commodity ID: TOC-800S
    • 产品卖点1: 1300℃ catalytic NDIR, 0.05-35000mg/L
    • 产品卖点2: External PC & audit trail, GMP/21 CFR 11
    • 产品卖点3: Solid/auto sampler, 3-stage cond, 100g/L

    Product Details

    10.4-inch observation window to

    view instrument operating status

    Windows operating system with

    full audit trail function

    Optional solid sampler; easily handles

    detection of solid and particulate samples.

    Optional autosamplers

    (24 position / 30 position / 70 position / 81 position) save labor.

     
    Working Principle  

    The sample is completely combusted at high temperature in the combustion furnace using a high-performance oxidation catalyst, decomposing it into carbon dioxide and water vapor. The water vapor is removed after cooling in a condenser, and the CO₂ is measured by a non-dispersive infrared (NDIR) detector to determine total carbon (TC) content. Separately, the inorganic carbon in the sample is decomposed into CO₂ and water vapor by an acid reagent; after condensation, CO₂ is measured by NDIR to determine total inorganic carbon (TIC) content. Total organic carbon (TOC) is then calculated as TOC = TC – TIC.

     

    Measurement Modes
    ModeOperating Principle
    TC modeDetermines total carbon in the sample. The sample in the UV reactor is decomposed into CO₂ under the action of oxidant, acid reagent, and UV.
    TIC mode

    Determines inorganic carbon (carbonate and bicarbonate) in the sample. In the UV reactor, carbonate and bicarbonate are decomposed into

    CO₂ by acid reagent.

    TOC mode

    Determines organic carbon in the sample. TOC is measured by difference: TOC = TC – TIC. The sample sequentially measures TC and TIC;

    The TOC obtained by difference includes both volatile and nonvolatile organic carbon.

    NPOC mode

    Determines non-purgeable organic carbon in the sample. In the UV reactor, inorganic carbon is decomposed by acid reagent to CO₂ and

    purged, while volatile organic compounds are also purged. The remaining organic carbon is then decomposed into CO₂ by oxidants,

    acid reagents, and UV.

     

    Standards

    ISO 8245  
    China National Environmental Protection Standard HJ 501-2009  
    China National Metrological Verification Regulation JJG 821-2005

     

    Applications

    Tap water, surface water, rivers, lakes  
    Domestic sewage, industrial wastewater  
    Chemical process water (cleaning water, cooling water, recycled water, etc.)  
    Laboratory research


    Software Description

    The software meets GMP computerized system validation requirements:         
    Electronic Signature       
    Login via username and password, each unique.         
    Password length requirements enhance security.         
    The manual screen lock function ensures operational uniqueness and safety.         
    Access Control       
    Multi-level permission settings.         
    Administrators can assign different permissions to operators, ensuring personnel only have privileges commensurate with their job functions.         
    Data Integrity        
    The audit trail function is enabled and cannot be turned off.         
    All test results are saved and cannot be modified or deleted.         
    All operations (any user entry) are recorded.         
    If a test method is modified, the changed parameters are recorded.         
    Data can be exported and backed up to protect stored data for future retrieval.

     

    Features

    Three-pass electronic condensation dehydration technology ensures system dehydration efficiency.  
    High-reflectivity gold-plated gas cell, a high-concentration infrared light source, and a high-sensitivity infrared detector guarantee excellent NDIR performance and sufficient sensitivity and accuracy for ppb-level measurements.  
    Real-time visible detection curve.  
    Multiple real-time self-monitoring for temperature, pressure, and flow rate.  
    Combustion furnace heating with multi-protection: automatically cuts off heating in case of overheating, improving product safety.  
    A built-in needle printer saves bench space.  
    Two-year data storage with convenient time-based queries.  
    Password protection.  
    Maximum furnace temperature is 1300 ℃ (far above 680 ℃), greatly improving oxidation efficiency, meeting detection requirements for almost all substances, and enhancing accuracy and stability.  
    Choice of catalysts (CeO, Pt, CuO) and adjustable temperature for flexible experimental conditions.  
    Automatic liquid sample injection saves labor and time; a precision electromagnetic metering pump ensures accuracy, stability, and continuous uniform injection, avoiding fluctuations due to individual operation differences; nonmanual injection reduces human contact with liquids, improving safety.  
    A heated inorganic carbon reactor eliminates peak tailing, shortening measurement time.  
    Optional solid sampler for boat injection of solid samples (soil, sludge, etc.); wide application range.  
    Optional online module for continuous monitoring.  
    Optional automatic sampler for unattended operation, saving labor and time.

     

    Specifications

    ParameterValue
    Analysis methodHigh-temperature catalytic oxidation – NDIR detection
    TOC detection range0.050 – 35,000 mg/L
    Carrier gasHigh-purity oxygen (99.999%)
    Salt tolerance100 g/L
    Analysis time3–8 min
    Accuracy error±5%
    Repeatability error≤3%
    Ambient temperature0–60℃ ± 5 ℃/D
    Relative humidity≤90%
    Detectable itemsTC, IC, TOC, NPOC
    Injection volume20–1000 μL
    Furnace temperatureUp to 1300 ℃
    Acid reagentPhosphoric acid solution
    TOC detection precision0.001 mg/L
    Zero drift±2%/D
    Span drift±2%/D
    Power supply220 ± 22 V AC, 50 ± 1 Hz
    Power800 W
    Dimensions (W×D×H)59.5 cm × 42.5 cm × 45.5 cm
    Weight44 kg

     

    Ordering Information

    ModelOrder No.Electrical RequirementsConfiguration Description
    TOC-800S106001012220 ± 22 V AC, 50 ± 1 Hz 

    Standard: main unit, combustion furnace, NDIR detector, catalyst, external control software;

    optional solid sampler/autosampler

DOWNLOAD

PRODUCTS FAQ

When can I get the price?

We usually quote as soon as we get your inquiry. If you need urgent reply, please tell us your email or WhatsApp account, we will contact you ASAP.

How long is the quotation valid?

In general ,our prices are valid for one month from the date of quotation. Prices will be adjusted appropriately based on price fluctuations in raw materials and market changes.

How are products transported? How can get the shipping cost?

You tell us your destination port or delivery address, we check the Sea Freight, Air Freight or Express Freight for you based on your requirement. By Sea: Cost-effective for large, heavy equipment. By Air: Fast and safe for urgent or sensitive orders. By Express: Door-to-door delivery via DHL, FedEx, or UPS for smaller items.

Have Questions? Get in Touch!

Please fill out this form and we will get in touch with you shortly.

%{tishi_zhanwei}%
Quote List
Close
  • Inquiry
Close
Clear all