Total Organic Carbon Analyzer
Total Organic Carbon Analyzer
Total Organic Carbon Analyzer
+
  • Total Organic Carbon Analyzer
  • Total Organic Carbon Analyzer
  • Total Organic Carbon Analyzer

Total Organic Carbon Analyzer

TOC-900


The TOC-900 Total Organic Carbon (TOC) Analyzer is an instrument for determining TOC concentration in water samples. It can detect TOC concentrations ranging from 0.1 µg/L to 20.0 mg/L, featuring high sensitivity, accuracy, and excellent stability. This TOC analyzer broadly meets customer requirements. The software is easy to operate, enabling rapid sample analysis, instrument calibration, and verification.

Key Features

Membrane cond., 0.1µg/L-20mg/L, ≤2% repeat

No carrier gas, 10.2" touch/PC, 4min test

USP/ChP/21 CFR 11, audit trail, autosampler

Facebook
YouTube
LinkedIn
    • Brand: LabNav
    • Commodity name: Total Organic Carbon Analyzer
    • Commodity ID: TOC-900
    • 产品卖点1: Membrane cond., 0.1µg/L-20mg/L, ≤2% repeat
    • 产品卖点2: No carrier gas, 10.2" touch/PC, 4min test
    • 产品卖点3: USP/ChP/21 CFR 11, audit trail, autosampler

    Product Details

    Working Principle  

    The TOC-900 uses ultraviolet radiation and a chemical oxidant (persulfate) to oxidize organic compounds, producing carbon dioxide (CO₂). The analyzer measures CO₂ using a sensitive, selective membranebased conductivity detection technique. For TOC measurement, the total inorganic carbon (TIC) concentration is determined first. After oxidation of organic compounds, the total carbon (TC) content is measured. The organic carbon concentration equals TC minus TIC (TOC = TC – TIC).

     

    Standards

    USP <643> Total Organic Carbon (TOC) method 
    Chinese Pharmacopoeia 2020, Vol. IV, 0682 – Determination of total organic carbon in water for injection 
    GMP Annex – Computerized System Validation 
    21 CFR PART 11 
    JJG821-2005 National Metrological Verification Regulation – Total Organic Carbon Analyzer

     

    Applications

    Pharmaceutical industry: Purified water, water for injection, sterile water for injection, etc. 
    Cleaning validation rinse water 
    Semiconductor industry: Electronic-grade process water 
    Thermal power generation: Boiler feed water, boiler makeup water, steam condensate


    Software Description

    The software meets GMP computerized system validation requirements: 
    Electronic Signature  
    Login via username and password, each unique. 
    Password length requirement enhances security. 
    Manual screen lock function ensures operational uniqueness and safety. 
    Access Control  
    Multi-level permission settings. 
    Administrators can assign different permissions to operators, ensuring personnel only have privileges commensurate with their job functions. 
    Data Integrity  
    Audit trail function is enabled and cannot be turned off. 
    All test results are saved and cannot be modified or deleted. 
    All operations (any user entry) are recorded. 
    If a test method is modified, the changed parameters are recorded. 
    Data can be exported and backed up for future retrieval.

     

    Features

    Membrane conductivity measurement technology achieves high accuracy testing for low concentration TOC water samples, improves instrument anti-interference, and enhances testing stability and measurement precision. 
    No carrier gas required, reducing equipment maintenance cost and making operation more convenient. 

    Embedded 10.2-inch touch screen, can be operated directly via touch screen or connected to a computer.
    Two sets of software systems are available to meet customer testing requirements.
    Multi-level password access control. 
    Automatic lock-on-leave protection. 
    Sample traceability – each sample has a unique number. 
    Complies with USP <643>, EP <2.2.44>, and Chinese Pharmacopoeia 2020, Vol. IV, Chapter 0682 "Total Organic Carbon Determination in Pharmaceutical Water." 
    Built-in system suitability test method required by USP <643>, EP <2.2.44> and Chinese Pharmacopoeia 0682. 
    Large memory automatically stores all test data—any test record can be queried and printed. 
    Fast analysis – single test analysis time ≤4 minutes. 
    Over-limit alarm output function. 
    Optional automatic calibration kit—one key automatic calibration and system suitability test. 
    Optional automatic sampler for unattended operation, saving labor and time.

    Also see accessories.

     

    Specifications

    TOC Detection Range0.1 µg/L – 20.0 mg/L
    TOC Accuracy Error±4%
    Analysis Time4 min
    OxidantSodium persulfate solution
    Flow Rate0.5 ml/min
    Repeatability Error≤2%
    Ambient Temperature0–60 ℃±5 ℃/D
    Relative Humidity≤90%
    Response TimeWithin 10 min
    Sample Temperature0–100 ℃
    TOC Detection Precision0.1 µg/L
    Acid ReagentPhosphoric acid solution
    Zero Drift±2%/D
    Span Drift±2%/D
    Power Supply220 ± 22 V AC, 50 ± 1 Hz
    Power Consumption150 W
    Dimensions (W×D×H)50 cm × 40 cm × 42 cm
    Weight30 kg
    ConsumablesAlso see accessories.

     

    Ordering Information

    ModelOrder No.Electrical RequirementsConfiguration Description
    TOC-900106001015220 ± 22 V AC, 50 ± 1 Hz

    Standard: UV oxidation main unit, membrane conductivity detector, reagents and tubing;

    optional automatic calibration kit/sampler

  • Optional Accessories

     

     

     

     

    An optional autosampler (24-position / 30-position / 70-position / 81-position) saves labor. 

     

     

     

     

    Consumables List
    NameSpecification/ModelReplacement Cycle
    UV lampUV6005000 h
    Peristaltic pump tube1 year
    Acid reagentPhosphoric acid solutionAs consumed
    OxidantSodium persulfate solutionAs consumed

DOWNLOAD